| Model | ASP4880S180-H | ASP48100S200-H | |||||
| INVERTER OUTPUT | |||||||
| Rated Output Power | 8,000W | 10,000W | |||||
| Max. Output Power | 16,000VA | 20,000VA | |||||
| Rated Output Voltage | 230Vac, single-phase | ||||||
| Load capacity of Motors | 5HP | 6HP | |||||
| Rated AC Frequency | 50/60Hz | ||||||
| Waveform | Pure sine wave | ||||||
| Output Mode | Off-grid (default) / power the load without battery | ||||||
| Switch Time | 10ms(typical) | ||||||
| BATTERY | |||||||
| Battery Type | Li-ion / Lead-acid / User-defined | ||||||
| Rated Battery Voltage | 48V | ||||||
| Battery Voltage Range | 40~60Vdc | ||||||
| Max. Solar Charging Current | 180A | 200A | |||||
| Max. Grid/Generator Charging Current | 100A | 120A | |||||
| Max. Hybrid Charging Current | 180A | 200A | |||||
| SOLAR INPUT | |||||||
| No. Of MPPT | 2 | ||||||
| Max. PV Array Power | 5,500W+5,500W | ||||||
| Max. Input Current | 22A+22A | ||||||
| Max. Open Circuit Voltage | 500Vdc+500Vdc | ||||||
| MPPT Voltage Range | 125~425Vdc | ||||||
| GRID/GENERATOR INPUT | |||||||
| Input Voltage Range | 90~275Vdc | ||||||
| Input Frequency Range | 50/60Hz | ||||||
| Bypass Overload Current | 63A | ||||||
| EFFICIENCY | |||||||
| MPPT Tracking Efficiency | 99.9% | ||||||
| Max. Efficiency | 92% | ||||||
| GENERAL DATA | |||||||
| Parallel Capacity | 1~6 Units (More than 3 units in parallel can form a three-phase output) | ||||||
| Dimension | 620*445*130mm | Noise | <60dB | ||||
| Weight | 27kg | Cooling Method | Built-in fan | ||||
| Protection Degree | IP20 Indoor Only | Warranty | 2 years | ||||
| Temperature | -10-55°C, >45°C Derate | Communication | RS485/CAN/USB/Dry Contact | ||||
| External Module (Optional) | Wi-Fi/GPRS | Topology | Transformerless | ||||
| Certificate | RoHs / EN61000-6-1 / EC61000-6-3 / FCC Part15 Class B/ IEC62109-1 / IEC62109-2 / IEC62477 / IEC62040 / NRS097-2-1 | ||||||
| PROTECTION | |||||||
| Has PV input current limiting protection, PV input over-voltage, PV night reverse current protection, AC input over- voltage protection, AC input under-voltage protection, Battery over-voltage protection, Battery under-voltage Protection, Battery over-current protection, AC output short-circuit protection, Heat sink over-temperature protection, Inverter over-load protection. | |||||||